(While navigating through the site, please be sure to disable your pop-up blocker.)
Stationary Engineer
The Research and Administrative Facilities (RAF) department manages the operations and maintenance of research and administrative buildings, including both the Bastrop and Smithville campuses. The RAF team also includes parking and transportation, audio visual and event operations, as well as the exterior site operations, all of which support all the Houston campuses and properties.
The RAF team values honesty, openness, empowerment and expects everyone to lead by example. We strive to be a group of high performing individuals, unified as a team, providing excellent customer service in an efficient and timely manner. We embrace the 1-Team, 1-Mission, 1-Division philosophy. As a team they truly work each day to contribute to Making Cancer History.
Ideal candidate will have a First or Second Grade Licensed Stationary Engineer as issued by the City of Houston, a valid Class A, B, or C Texas driver’s license and experience of 4 or more years working with boiler systems, chiller/cooling towers, and water treatment systems.
Position is a Monday – Friday 7:00 AM to 3:30 PM.
Salary Range: $57,500 - $72,000 - $86,500
MD Anderson offers our employees:
- Paid employee medical benefits (zero premium) starting on first day for employees who work 30 or more hours per week
- Group Dental, Vision, Life, AD&D and Disability coverage
- Paid time off (PTO) and Extended Illness Bank (EIB) paid leave accruals
- Paid institutional holidays, wellness leave, childcare leave, and other paid leave programs
- Tuition Assistance Program after six months of service
- Teachers Retirement System defined-benefit pension plan and two voluntary retirement plans
- Employer paid life, AD&D and an illness-related reduced salary pay program
- Extensive wellness, recognition, fitness, employee health programs and employee resource groups.
Why Join MD Anderson?
Be part of a world-renowned cancer center making an impact across Texas and beyond.
Collaborate with top-tier leaders and institutions in academic medicine
Help shape the future of healthcare through bold, system-wide innovation
Work with a Mission-Driven Organization: Be part of MD Anderson's mission to eliminate cancer through integrated patient care, research, and education, contributing to a globally recognized institution with a meaningful purpose.
SUMMARY
The primary purpose of the Stationary Engineer position is to provide skilled work in the operation of a central chilled water and steam system physical plant. This position impacts the maintenance of equipment and machinery within the institution.
ESSENTIAL JOB FUNCTIONS
Performs preventative maintenance, correctives and inspections on electric/steam boilers, chillers, cooling towers and associated pumps. Start up, coordinate equipment run scenarios, and monitor/troubleshoot chillers, towers and boilers via BAS system. Perform chemistry analysis, make necessary adjustments, data gathering and condition assessments on cooling tower, chilled water and boiler feed water. Perform testing, chemical treatment and preventative maintenance/correctives for Public Drinking Water System and associate assets. Cleans and maintains all equipment and work areas.
JOB SPECIFIC COMPETENCIES
Work Plan & Documentation Interprets and works from blueprints, sketches and diagrams. Estimates cost of work and may order materials and maintain inventory. Discusses issues, concerns and process improvement options with Sr. Stationary Engr and Supervisor. Responsible for completing work order and asset documentation according to CMMS Standards. Provides accurate information on labor hours & material used to complete the work, work preformed, notes any additional required work &/or asset information.
Preventive Maintenance Performs Preventive Maintenance on central plant equipment according to manufacturer’s specifications and CMMS directed work.
Corrective Maintenance Installs, maintains and repairs variety of central plant equipment plumbing work incidental to the installation and repair of electric/steam boilers, chillers, cooling towers, valves, steam lines, boilers, pipes, other equipment and associated pumps. The start up, coordinate equipment run scenarios, and monitor/troubleshoot chillers, towers and boilers via BAS system. Perform chemistry analysis, make necessary adjustments, data gathering and condition assessments on cooling tower, chilled water and boiler feed water. Perform testing, chemical treatment and preventative maintenance/correctives for Public Drinking Water System and associate assets. Cleans and maintains all equipment and work areas. Checks and changes charts, takes meter readings and analyzes water.
Team and Work Load Support Investigates outages, supports or preforms other work as necessary in the management the work load
On-Call The employee may be expected to be part of an on-call group, and when assigned this responsibility, will be compensated for that time. When on-call, the employee must be available and be able to respond in accordance to policy. Periods of alert when Emergency Conditions may be expected are not considered on-call.
Essential Personnel This position is considered “essential personnel” in the event of suspension of normal operations due to inclement weather or other emergencies. They are required to perform duties as outlined in the Emergency Management Plans.
Incidental Work Other incidental or related duties as required.
Other duties as assigned
EDUCATION
- Required: High School Diploma or Equivalent
- Preferred: Vocational school or apprenticeship training.
WORK EXPERIENCE
- Required: 4 years Experience working with boiler systems, chiller/cooling towers, and/or water treatment systems in a large central physical plant.
LICENSES AND CERTIFICATIONS
- Preferred: First or Second Grade Licensed Stationary Engineer as issued by the City of Houston.
- Preferred: Class D Water Operator license issued by the Texas Commission on Environmental Quality.
- Preferred: UC-EPA - Universal Certification Universal Certification by the Environmental Protection Agency (EPA).
- Preferred: TDL - Texas Drivers License Valid Class A, B or C Texas driver's license and eligible to drive State and institutional vehicles.
The University of Texas MD Anderson Cancer Center offers excellent benefits, including medical, dental, paid time off, retirement, tuition benefits, educational opportunities, and individual and team recognition.
This position may be responsible for maintaining the security and integrity of critical infrastructure, as defined in Section 113.001(2) of the Texas Business and Commerce Code and therefore may require routine reviews and screening. The ability to satisfy and maintain all requirements necessary to ensure the continued security and integrity of such infrastructure is a condition of hire and continued employment.
It is the policy of The University of Texas MD Anderson Cancer Center to provide equal employment opportunity without regard to race, color, religion, age, national origin, sex, gender, sexual orientation, gender identity/expression, disability, protected veteran status, genetic information, or any other basis protected by institutional policy or by federal, state, or local laws unless such distinction is required by law.http://www.mdanderson.org/about-us/legal-and-policy/legal-statements/eeo-affirmative-action.html